Application Note 003:JTAG Cable Considerations

It is important to understand that when you connect the Universal Scan cable, that you are literally adding a 6-foot antenna to your board.  That can inject noise into your system, and it can interact with your JTAG circuit layout to create extra TCK pulses that mess everything up.

The best way to avoid all these issues is to treat the JTAG signals like you would any other test signal: buffer them as they enter/leave the board. Or, if that is not an option due to cost or space limitations, build a little buffer board that you can attach between the cable and the board.

If that is still too much, then you can usually get away with simply placing a resistor in series with the JTAG signals (or at the very least, TCK and TDO). Something around 220 ohms to 1K ohms will do for most situations. Also, try to make sure the TCK signal is not coupling with the other three. Twisting TCK and GND right at the end of the cable can make all the difference in the world.

Let’s look at some examples:

Here is a picture of a clean TCK and TDO signal:

Picture of clean TCK and TDO Boundary Scan Signals.





.. and here is the cable configuration that generated it: 

JTAG cable configuration for generating TCK & GND signals separated from other JTAG signals.






As you can see, simply keeping TCK away from the other signals helps a lot.
 

Now, lets couple TCK and TDO and see what happens. We’ll do that by wrapping TCK and TDO around each other and separating them from the rest of the signals: 

JTAG cable with TCK&TDO tightly coupled and separated from other JTAG signals.






The effect on TCK is dramatic: 

Picture shows dramatic effect on TCK from tightly coupled TCK&TDO






That was only about 3 or 4 inches of wire that we wrapped.  That means you need to be real careful not to run TDO and TCK close to each other on your circuit board.

TDO is the key. TMS and TDI are not a concern with Universal Scan since they change well away from any TCK edge.
 

SIMPLE FIX: If we take the exact same example as above and simply insert a 220 ohm resistor in series with TCK only, right at the connector, the result looks like this:

Picture shows result of inserting 220 ohm resistor in series with TCK only, right at the connector.






The same result is achieved by inserting a 220 ohm resistor in series with the TDO signal by itself. For double protection, you should always do BOTH!
 

Here is an example of a 1K ohm resistor in series. Same net result, but TCK is starting to get stretched out:

If you use a resistor that is too large, TCK slope becomes stretched out and  scan chain will stop functioning

If you use a resistor that is too large, TCK’s slope will become too stretched out and the chain will stop functioning again. Experiment with your circuit, to find the best value using the above as a guideline.

If you were to dissect the Universal Scan cable, you would find that TCK and TDO are kept as far apart as possible at all times down the full length of the cable.

Similarly, you should be careful to keep TDO and TCK separated at the JTAG header on your board.

SUMMARY CHECKLIST:

1. Keep TCK & TDO separate at all times in your layout, including the JTAG header.
2. Keep TCK & TDO separate on the flying leads of the cable.
3. Buffer all test signals as they enter/leave the board.
4. You can use resistors to soften transitions and minimize coupling.
5. Don’t forget to watch the fan-out of the TCK & TMS signals. Re-buffer as appropriate.
6. You can use resistors to soften transitions and minimize coupling.

 